HelixNet 4-Channel 1 RU Digital Main Station

SKU
SP100989

Ships Directly from Manufacturer. Contact Us for Availability.

Brand
$4,910.00
Overview
The HMS-4X is a 1U digital Partyline main station with 12 channels of full-duplex audio and program audio feed that can support up to 60 beltpacks on a single station (beltpacks sold separately). The user can listen in via the integrated speaker or headse

File(s)

FEATURES:
4-Channel 1 RU Digital Main Station

HelixNet System Operation:
• HelixNet System Master
• 6 HMS can link over LAN and WAN
• Supports up to 64 endpoints on HelixNet system
• 12 Partyline channels. Expandable to 24 channels via optional license
Main Station:
• Easy to use CCM browser configuration
• Fast front panel control and configuration
• Plug-and-go with auto discovery
• Central upgrades from main station
User Station:
• Headset or hands-free support with speaker and mic
• 4 Keysets freely assignable to channels
• All Talk, Stage Announce, RMK and Program Audio level controls
Connectivity:
• 2 Powerlines for distribution of Ethernet to HelixNet user stations via XLR cables
• 3 Expansion slots for HLI modules: Ethernet, fiber, 2-wire and 4-wire ports
• Program Audio input and Stage Announce output
• 4 Contact closure inputs and outputs
LQ Integration Options:
• LQ linking for high density 2-wire, 4-wire and GPIO expansion
• Agent-IC natively integrated via optionally licensed LQ
• SIP/VoIP integrated via optionally licensed LQ
The HelixNet HMS-4X main station is a combination of a system master and an intercom user station with XLR Powerline connections to user stations. HMS-4X hosts up to three HLI interface modules for external connectivity, including Ethernet and Fiber.

SPECIFICATIONS:
Linking
HMS is required as the HelixNet Master. Link Group may include five additional HMS Members, including up to three LQ devices for a maximum of six HMS/LQ in Link Group. HMS link using HLI-ET2 or HLI-FBS modules over LAN/WAN connections. Link Group supports up to 64 endpoints (station/port).
Channels
System provides 12 or 24 intercom channels assignable to any user station or port in the system. Four Channels can be assigned to station. Program Audio can be associated with any channel with independent endpoint level control.
Roles
99 Roles for naming and dynamic configuration of user station settings. Role can be applied to multiple user stations.
Connectors
XLR Powerline: (2) Powerline, 3-pin XLR-M/F
Headset: 4-pin XLR–M
Program Audio: 3-pin XLR–F
Stage Announce: 3-pin XLR–M
Hot Mic/IFB Interface: 1/4? (6.35 mm) TRS Jack
GPIO: 25-pin D-type female (4 GPI, 4 GPO, 5V)
USB: Type A & Micro AB (factory service use)
Microphone Preamplifier
Headset Mic Impedance: 200O (Dynamic)
Headset Mic Voltage: 1.7V (Electret selectable)
Limiter: +23 dB
Route to 4-wire output at 0 dBu:
Mic Gain: 60 dB (Dynamic), 45 dB (Electret)
Frequency Response: 200 Hz – 10 kHz ±3 dB
Distortion: <0.2% THD @ 1 KHz
Noise: <-55 dBu (Dynamic), <-65 dBu (Electret)
Headphone Amplifier
Load Impedance: >32O
Output Level: +12 dBu before clipping
Sidetone: -12 dB (selectable)
Route from a 4-wire input at 0 dBu:
Max Gain: 0 dB
Frequency Response: 40 Hz – 10 KHz ±3 dB
Distortion: <0.1% THD @ 1 KHz
Noise: <-65 dBu
Headphone Limiter: 0 dB (selectable)
Loudspeaker Amplifier
Load Impedance: 8O
Output Level: +18 dBu before clipping
Route from a 4-wire input at 0 dBu:
Max Gain: 18 dB
Frequency Response: 200 Hz – 10 KHz ±3 dB
Distortion: <0.1% THD @ 1 KHz
Noise: <-50 dBu
Program Audio Line Input
Maximum Level Before Clipping: +18 dBu
Nominal Input Level: 0 dBu (selectable)
Input Impedance: >= 10 KO
Route to 4-wire output at 0 dBu:
Frequency Response: 20 Hz – 10 KHz ±3 dB
Distortion: <0.2% THD @ 1 KHz
Noise: <-65 dBu
Stage Announce Output
Maximum Level Before Clipping: +18 dBu
Nominal Output Level: 0 dBu (selectable)
Output Impedance: <= 100O
Route from a dynamic headset:
Frequency Response: 300 Hz – 12 KHz ±3 dB
Distortion: <0.1% THD @ 1 KHz
Noise: <-55 dBu
Hot Mic Output
Maximum Level Before Clipping: +12 dBu
Nominal Output Level: 0 dBu (selectable)
Output Impedance: <= 100O
Route from a dynamic headset:
Frequency Response: 300 Hz – 12 KHz ±3 dB
Distortion: <0.2% THD @ 1 KHz
Noise: <-55 dBu
Powerline
Two independent network XLR Powerlines
Frequency Modulated Ethernet – OFDM
Output Voltage: ±29.5V DC
Output Current (Max): 1.5A per Powerline
Frequency: 100 kHz - 25 MHz
Requires shielding integrity between Powerlines
Support up to 10 beltpacks each
Support up to 3-10 stations each
Use HelixNet Cable Calculator to validate load and cable distance.
Power
Input Frequency Range: 100 – 240V AC
Input Frequency Range: 50 – 60 Hz
Power (Max): 250W
Input Power Connector: IEC-C14
Practical Power Range:
Power (Normal): 80-250W
BTU (Normal): 275-850 BTU/hr
Dependent on hosted modules and powerline connected beltpacks
Environmental
32º – +104ºF (0 – +40ºC)
90% relative humidity
Dimensions
1.75 x 19 x 13 in (HxWxD)
(44 x 483 x 320 mm)
Weight
5.83 lb. (2.65 kg)
Network Specifications (Version 4)
Network Protocols
Ethernet IPv4 – Unicast Audio and Control
mDNS – Multicast Device Discovery
Layer 3 – Routable with mDNS function limitations
WavPack – Audio Codec
Network Ports
Unicast:
Port 80 TCP – Web Interface, System Management, Expansion
Port 655 TCP – Link Group Audio/Database
Port 6001 TCP – System Management
Port 6001 UDP – Audio Streams
Multicast:
Port 5353 UDP – mDNS, Names, Discovery, Linking, Expansion
Optional for device names and linking
Mandatory for HMS/HRM Expansion
Network Parameters
Link Group Endpoint Support: 64 Endpoints are user stations, active Interface ports, Program Audio inputs and LQ accounts.
Bandwidth:
300 kbps each audio input linking between HMS/LQ
Link Group audio sent dynamically between members
300-600 (max) kbps from each audio input to HMS
1200-2400 (max) kbps from HMS to each endpoint audio output
Network Jitter Tolerance:
<= 128 ms jitter buffer per audio stream receiver automatically adjusted to network performance
QoS Tags:
DSCP=46, High Priority/Expedited Forwarding (EF)
Link-Local Default IP Address Range:
169.254.0.0/16
System Reserved IP Ranges:
10.0.0.0/8 for endpoints
172.23.0.0/16 for Link Group
Recommended Ethernet Switches
Managed Ethernet Switch – Layer 3
100/1000 Base-T ports for endpoints
1000 Base IP Trunks between switches
QoS Configuration
Energy Efficient Ethernet bypass option
IGMP Snooping bypass option
More Information
Weight 5.830000
Length 19
Width 13
Height 1.75
Color Black
Manufacturer Clear-Com
Manufacturer Model Number HMS-4X
Manufacturer Part Number HMS-4X
Write Your Own Review
You're reviewing:HelixNet 4-Channel 1 RU Digital Main Station