The DriveCore install series amplifiers is a complete line of high performance installation amplifiers based on the proprietary DriveCore technology. DCi Series amplifiers are designed, engineered and manufactured to the industry’s highest quality standards, and provide system integrators with the advanced features and flexibility required for challenging 21st century installed sound applications. Versatile, compact and highly energy-efficient, DCi Series amplifiers continue the unbroken Crown tradition of leadership in professional and commercial power amplifier technology. This amplifier is EN 54-16 Compliant for life safety applications.
Features
ANALOG & DIGITAL INPUTS – With digital audio transport via HARMAN’s proprietary BLU-Link, plus balanced analog inputs, DCi gives you a tremendous audio advantage – at a much lower cost. The priority input router allows you to specify a primary input, and if audio is lost the amp automatically switches to the other input.
NETWORK MONITORING & CONTROL – Better monitoring, control and audio manipulation with the HiQnet protocol that’s over standard TCP/IP. Remotely see how all networked DCi amplifiers are performing and control them as needed. In addition, this allows Audio Architect software and the Powered by Crown app to work with DCi amplifiers.
PROGRAMMABLE GENERAL PURPOSE INPUT/OUTPUT PORTS – GPIO ports can be configured in many different ways, such as volume controls, recall presets, or to report errors to a master computer.
DIGITAL SIGNAL PROCESSING – DSP capabilities include the following:
- LevelMAX Limiters
- Input/Output EQ
- Crossover
- Delay
- Matrix Mixer
- Speaker Line Monitoring
EN 54-16 Compliant for Life Safety Applications - Part 16 of the European Union’s (EU) EN 54 standard for fire detection and alarm systems has a specific requirement for voice alarms, which output messages in the form of a voice message rather than a traditional siren. This amplifier is certified as part of an EN 54-16 VACIE*, meeting the stringent requirements of a life safety system to serve the needs of hospitality, large venue and other markets.
Features
ANALOG & DIGITAL INPUTS – With digital audio transport via HARMAN’s proprietary BLU-Link, plus balanced analog inputs, DCi gives you a tremendous audio advantage – at a much lower cost. The priority input router allows you to specify a primary input, and if audio is lost the amp automatically switches to the other input.
NETWORK MONITORING & CONTROL – Better monitoring, control and audio manipulation with the HiQnet protocol that’s over standard TCP/IP. Remotely see how all networked DCi amplifiers are performing and control them as needed. In addition, this allows Audio Architect software and the Powered by Crown app to work with DCi amplifiers.
PROGRAMMABLE GENERAL PURPOSE INPUT/OUTPUT PORTS – GPIO ports can be configured in many different ways, such as volume controls, recall presets, or to report errors to a master computer.
DIGITAL SIGNAL PROCESSING – DSP capabilities include the following:
- LevelMAX Limiters
- Input/Output EQ
- Crossover
- Delay
- Matrix Mixer
- Speaker Line Monitoring
EN 54-16 Compliant for Life Safety Applications - Part 16 of the European Union’s (EU) EN 54 standard for fire detection and alarm systems has a specific requirement for voice alarms, which output messages in the form of a voice message rather than a traditional siren. This amplifier is certified as part of an EN 54-16 VACIE*, meeting the stringent requirements of a life safety system to serve the needs of hospitality, large venue and other markets.
SPECIFICATIONS:
Frequency Response (8O, 20 Hz - 20 kHz): ±0.25 dB
BLU Link Input Signal to Noise Ratio (A-Weighted): >104 dB
Total Harmonic Distortion (at full rated power, 20 Hz - 20 kHz): 0.35%
Voltage Gain: 34 dB
Damping Factor (20 Hz to 100 Hz): >1000
Input Impedance (nominal balanced, unbalanced): 10kO, 5kO
Maximum Input Level before Compression: +20 dBu
Load Impedance (Stereo/Dual Mode): 2O - 16O; 70 Vrms and 100 Vrms
Load Impedance Bridge Mono: 4O - 16O; 140 Vrms and 200 Vrms
Cooling: Continuously variable speed forced air, front to back airflow
Maximum Fan Noise (re dBA SPL @ 1M): 45
Required AC Mains (±10%): 100 V - 240 V ~ 50/60 Hz
Power Connector: 15A IEC
Dimensions: 19" x 3.5" x 14.25" (48.3 cm x 8.9 cm x 35.63 cm)
Weight: 20.1 lb. (9.12 kg)
Frequency Response (8O, 20 Hz - 20 kHz): ±0.25 dB
BLU Link Input Signal to Noise Ratio (A-Weighted): >104 dB
Total Harmonic Distortion (at full rated power, 20 Hz - 20 kHz): 0.35%
Voltage Gain: 34 dB
Damping Factor (20 Hz to 100 Hz): >1000
Input Impedance (nominal balanced, unbalanced): 10kO, 5kO
Maximum Input Level before Compression: +20 dBu
Load Impedance (Stereo/Dual Mode): 2O - 16O; 70 Vrms and 100 Vrms
Load Impedance Bridge Mono: 4O - 16O; 140 Vrms and 200 Vrms
Cooling: Continuously variable speed forced air, front to back airflow
Maximum Fan Noise (re dBA SPL @ 1M): 45
Required AC Mains (±10%): 100 V - 240 V ~ 50/60 Hz
Power Connector: 15A IEC
Dimensions: 19" x 3.5" x 14.25" (48.3 cm x 8.9 cm x 35.63 cm)
Weight: 20.1 lb. (9.12 kg)
Weight | 20.100000 |
---|---|
Length | 19 |
Width | 14.25 |
Height | 3.5 |
Color | Black |
Compatibility | BLU Link |
Manufacturer | Crown by HARMAN |
Manufacturer Model Number | DCI4x300N |
Manufacturer Part Number | DCI4X300N-U-USFX |
UPC | 691991009037 |
Size | 4 Channels |
Write Your Own Review