$1,225.00
Ships Directly from Manufacturer. Contact Us for Availability.
SKU
SP95549
The eDIN #1016 DMX/RDM Hub brings flexibility to single universe DMX512 distribution systems.
Through use of automatic signal sensing, across four operating modes, any port may detect incoming DMX signals and act as an input; or two inputs may be merged; the user may choose between inputs; or a priority scheme may be invoked. RDM discoverable and configured.
FEATURES
• Eight bi-directional ports
• Four operating modes
• Simple UI for mode selection
• Automatically locates incoming DMX signal and routes according to current mode
• Act as automated signal patch bay
• Auto-termination of inputs
• Port direction LED indicators, as well as power and function
• E1.20 Remote Device Management support in routing modes
• Hold last look time and output speed user-settable by RDM
• Multi-level cascade of modules permitted
• Pluggable terminal block connections accept solid or stranded wire between #26 and #16 AWG
• Power easily daisy-chained between modules
Through use of automatic signal sensing, across four operating modes, any port may detect incoming DMX signals and act as an input; or two inputs may be merged; the user may choose between inputs; or a priority scheme may be invoked. RDM discoverable and configured.
FEATURES
• Eight bi-directional ports
• Four operating modes
• Simple UI for mode selection
• Automatically locates incoming DMX signal and routes according to current mode
• Act as automated signal patch bay
• Auto-termination of inputs
• Port direction LED indicators, as well as power and function
• E1.20 Remote Device Management support in routing modes
• Hold last look time and output speed user-settable by RDM
• Multi-level cascade of modules permitted
• Pluggable terminal block connections accept solid or stranded wire between #26 and #16 AWG
• Power easily daisy-chained between modules
MODES
• Mode 1 : RDM Hub
• Module detects and latches to a DMX input applied to any port. Automatically routes DMX signal to remaining ports as outputs. If a second source is applied, that source is ignored until the initial source stops.
• Mode 2 : RDM A/B Select
• Allows user selection, through use of dry contact closure, of input signal arriving at Port B to be selected and routed to the remaining ports, over signal arriving as input at Port A. When dry contact is open, the signal arriving at Port A will be routed.
• Mode 3 : Priority
• Provides predictable signal priority arrangements of DMX sources. Port A is given highest priority, Port H lowest. Module automatically senses DMX input on any port, and will route signal arriving at the highest priority port to the remaining ports as outputs. Module will automatically switch to any new signal arriving at a higher priority port, or fall back to the next lower priority signal when a signal stops.
• Mode 4 : Merge
• Provides HTP (highest-takes-precedence) merging of two DMX sources, regardless of which ports are used as inputs.
SPECIFICATIONS
• 250V fault protection on input and output ports
• Input operating voltage: 24-48 VDC
• 7W power consumption
• Operating conditions: -10 to +48°C; 10-90% relative humidity, non-condensing
STANDARDS COMPLIANCE
• ANSI E1.11 DMX512-A(2008)/USITT DMX512(1990)
• ANSI E1.20 RDM(2010) - Remote Device Management
• RoHS 2011/65/EU
• Class 2 Low Voltage
WEIGHTS AND DIMENSIONS
• 0.70 lb. (0.32 kg)
• 8.0” W x 4"H x 1.8” D (203 mm x 103 mm x 46 mm)
• Mode 1 : RDM Hub
• Module detects and latches to a DMX input applied to any port. Automatically routes DMX signal to remaining ports as outputs. If a second source is applied, that source is ignored until the initial source stops.
• Mode 2 : RDM A/B Select
• Allows user selection, through use of dry contact closure, of input signal arriving at Port B to be selected and routed to the remaining ports, over signal arriving as input at Port A. When dry contact is open, the signal arriving at Port A will be routed.
• Mode 3 : Priority
• Provides predictable signal priority arrangements of DMX sources. Port A is given highest priority, Port H lowest. Module automatically senses DMX input on any port, and will route signal arriving at the highest priority port to the remaining ports as outputs. Module will automatically switch to any new signal arriving at a higher priority port, or fall back to the next lower priority signal when a signal stops.
• Mode 4 : Merge
• Provides HTP (highest-takes-precedence) merging of two DMX sources, regardless of which ports are used as inputs.
SPECIFICATIONS
• 250V fault protection on input and output ports
• Input operating voltage: 24-48 VDC
• 7W power consumption
• Operating conditions: -10 to +48°C; 10-90% relative humidity, non-condensing
STANDARDS COMPLIANCE
• ANSI E1.11 DMX512-A(2008)/USITT DMX512(1990)
• ANSI E1.20 RDM(2010) - Remote Device Management
• RoHS 2011/65/EU
• Class 2 Low Voltage
WEIGHTS AND DIMENSIONS
• 0.70 lb. (0.32 kg)
• 8.0” W x 4"H x 1.8” D (203 mm x 103 mm x 46 mm)
Weight | 1.100000 |
---|---|
Length | 12 |
Width | 4.5 |
Height | 2.5 |
Manufacturer | Pathway Connectivity Solutions |
Manufacturer Model Number | 1016 |
Manufacturer Part Number | PWREP DIN P8 RDMHUB |
Size | 8" |
Write Your Own Review