$650.40
Ships Directly from Manufacturer. Contact Us for Availability.
SKU
SP101542
Source 4WRD II (Watt Reduction Device) LED is a replacement for a standard Source Four burner assembly that converts the HPL source to a white-light LED and provides a significant reduction in power consumption. The simple and quick upgrade is nondestructive and takes less than a minute. In most cases it can even be done without breaking the fixture’s focus. Source 4WRD II LED is theatrically dimmable via DMX or line dimmable, with a traditional LED curve, to allow flexibility for your installation. And, because it is an LED source, your fixtures will run cool and efficiently without lamp replacements
SPECIFICATIONS
Source:
LED details - S4WRD II LED
Max. lumens (3200 K / 3200 K Gallery / Daylight Gallery) 11,430 / 9,716 / 10,333
Lumens per watt (3200 K / 3200 K Gallery / Daylight Gallery) 120 V: 76.2 / 64.8 / 68.9
• 230 V: 65.3 / 55.5 / 59.0
L70 rating (hours to 70% output) >45,000 hours (LM84 test pending)
Color:
Colors used - Warm or Cool White
Color temperature range - 3200 K 80 or 90+ CRI, 5900 K 90+ CRI
Calibrated array - N/A
Red shift – No
Optical:
Field angle range - Swappable lens tubes between 5–90 degrees
Gate size - 79 mm
Aperture size - Lens dependent
Pattern projection - Yes
Pattern size - A or B (see manual)
Camera flicker control/ Hz range - No, not PWM dimmed
Control:
Input method - DMX Control or Line Dimmed
Protocols - DMX / RDM via RJ45
Modes (Footprint) - 1 Channel (Intensity) for DMX
RDM configuration - Yes UI type 7-segment address display, local level control via UI
Local control - Yes
Onboard presets - No
Onboard sequences - No
Onboard effects - No
Fixture to fixture control – No
Electrical:
Voltage range - 114–125 V, 60 Hz (120 V)
• 209–252 V, 50 Hz (230 V)
Input method - Hard wired, 1 m cord, Edison plug (120 V)
• Hard-wired, 1 m cord, bare end (230 V)
Inrush - 30 A (first half-cycle) at 120 V
• • 12 A (first half-cycle) at 230 V
Fixtures per circuit - 120 V: 14 (20 A switched circuit, R20 module or similar)
• 230 V: 6 fixtures per non-dimmed circuit (ER15AFR module)
Wattage (Typical/ Standby) - 150 W / 1.2 W (120 V)
• 175 W / 3.7 W (230 V)
Current draw - 1.26 A at 120 V
• • 0.75 A at 230 V
Notes - When using line dimming, see the S4WRD manual for dimmer setup. –
• When using line dimming, standby power is 0 W.
Thermal:
Ambient operating temp - 5°–50° C (41°–122° F)
Fan (controllable) - Yes (no)
Droop compensation - No
dB range - 28 dBa (average at 1 m)
BTUs/hour - 529 (120 V)
• • 597 (230 V)
Physical:
Materials - Die-cast aluminum
Color options - Black, white, or custom color
Mounting options - Yoke
IP rating - IP-20, indoor only
Weight - 3.73 lb. (1.69 kg) (Retrofit only)
Included accessories - Source 4WRD mounting post
Source:
LED details - S4WRD II LED
Max. lumens (3200 K / 3200 K Gallery / Daylight Gallery) 11,430 / 9,716 / 10,333
Lumens per watt (3200 K / 3200 K Gallery / Daylight Gallery) 120 V: 76.2 / 64.8 / 68.9
• 230 V: 65.3 / 55.5 / 59.0
L70 rating (hours to 70% output) >45,000 hours (LM84 test pending)
Color:
Colors used - Warm or Cool White
Color temperature range - 3200 K 80 or 90+ CRI, 5900 K 90+ CRI
Calibrated array - N/A
Red shift – No
Optical:
Field angle range - Swappable lens tubes between 5–90 degrees
Gate size - 79 mm
Aperture size - Lens dependent
Pattern projection - Yes
Pattern size - A or B (see manual)
Camera flicker control/ Hz range - No, not PWM dimmed
Control:
Input method - DMX Control or Line Dimmed
Protocols - DMX / RDM via RJ45
Modes (Footprint) - 1 Channel (Intensity) for DMX
RDM configuration - Yes UI type 7-segment address display, local level control via UI
Local control - Yes
Onboard presets - No
Onboard sequences - No
Onboard effects - No
Fixture to fixture control – No
Electrical:
Voltage range - 114–125 V, 60 Hz (120 V)
• 209–252 V, 50 Hz (230 V)
Input method - Hard wired, 1 m cord, Edison plug (120 V)
• Hard-wired, 1 m cord, bare end (230 V)
Inrush - 30 A (first half-cycle) at 120 V
• • 12 A (first half-cycle) at 230 V
Fixtures per circuit - 120 V: 14 (20 A switched circuit, R20 module or similar)
• 230 V: 6 fixtures per non-dimmed circuit (ER15AFR module)
Wattage (Typical/ Standby) - 150 W / 1.2 W (120 V)
• 175 W / 3.7 W (230 V)
Current draw - 1.26 A at 120 V
• • 0.75 A at 230 V
Notes - When using line dimming, see the S4WRD manual for dimmer setup. –
• When using line dimming, standby power is 0 W.
Thermal:
Ambient operating temp - 5°–50° C (41°–122° F)
Fan (controllable) - Yes (no)
Droop compensation - No
dB range - 28 dBa (average at 1 m)
BTUs/hour - 529 (120 V)
• • 597 (230 V)
Physical:
Materials - Die-cast aluminum
Color options - Black, white, or custom color
Mounting options - Yoke
IP rating - IP-20, indoor only
Weight - 3.73 lb. (1.69 kg) (Retrofit only)
Included accessories - Source 4WRD mounting post
Weight | 4.300000 |
---|---|
Length | 7 |
Width | 6.29 |
Height | 5.59 |
Color | Black |
Manufacturer | Electronic Theatre Controls |
Manufacturer Model Number | S4WRDT120-A |
Manufacturer Part Number | 7067A1112-A |
Write Your Own Review